Hydraulic pump cavitation is a devastating problem. It is the likely cause of symptoms such as excessive noise, energy use, pump damage, and pump failure.

Although each of these symptoms can indicate other concerns, cavitation is one of the most troublesome, as it can compromise the entire hydraulic system. It is the second leading cause of hydraulic pump failure behind hydraulic fluid contamination.

For this reason, let’s look at some of the causes of cavitation, how to recognize its occurrence, as well as how to prevent damage and keep hydraulic systems healthy.

What is cavitation and what causes it on hydraulic pumps?

Cavitation occurs from the formation of vapors and the resulting breakdown inside the hydraulic pump. Excessive vacuum conditions on the inlet (supply) side of the pump create steam bubbles within the hydraulic fluid which then travel to the discharge (pressure) side, at which point they collapse. The moment of collapse is when cavity damage occurs.

Cavitation is particularly destructive to metal surfaces, which have little flexibility. The explosive force of the cavitation causes friction and abrasion, which eventually leads to damage and, if left untreated, will lead to pump failure.

Although the main cause of cavitation is poor plumbing, there are many other ways in which this destructive force can begin.

Some of these other possible causes of cavitation in a hydraulic pump include:

flow restrictions

High oil viscosity

clogged filters

pipe blockage

poor tube design

Conditions that do not meet the requirements of NPSH (Net Positive Suction Head)

Determine the cavitation of the hydraulic pump

Most often, cavitation is audible, and is recognized by a recognizable sound. However, there are other visual cues that are accurate clues when the pump is experiencing cavitation.

When you are concerned that cavitation occurs in a hydraulic pump, pay attention to:

Sound: A hissing sound from the pump could indicate a slight cavitation, while a massive sound that might best be described as “glass balls in a can” could indicate severe explosions.

Physical Evidence: Metal debris found in a hydraulic oil filter during routine maintenance could indicate a cavity in the pump.

 


Damage: If the pump and its components are visibly damaged, it may be the result of cavitation and the pump requires immediate inspection.

Troubleshooting and prevention

If end users encounter cavitation, there are some easy troubleshooting practices that can fix the problem, limit damage, or help avoid the problem altogether.

Here are some preventive and troubleshooting steps you can take.

solving problems

Check filters and strainers for metal debris

Determine the available absolute pressure (NPSHa) and the required (NPSHr) at the suction port of the pump.

Check the viscosity of the oil and ensure it is suitable for the application and weather conditions

protection

Increase the fluid level around the suction area

Increase the pump suction line size to reduce turbulence

Maintain the appropriate oil viscosity for your components and based on the climatic/environmental conditions in which the pump is operating

Best practices to avoid cavitation

Continuing with a regular maintenance schedule for your hydraulic systems and looking for signs of cavitation is the best preventative measure that may actually include the above steps. However, there are some practices that can further protect hydraulic systems from bore damage.

These practices include:

Ensure hydraulic pumps are immersed in suction, i.e. use a direct path from the tank to the pump to use gravity and atmospheric pressure to operate the pump rather than relying on vacuum pressure to draw fluid.

Use a suitable vent cap on the tank, or compressed (3-5 psi) with an air system or pressure vent cap

Ensure that the supply line shut-off valves are fully open and free of restriction.

Check tank filter for buildup (if present)

Consider laminar flow and reduce noise and turbulence at the pump inlet by ensuring the length of the supply hose is at least 10 times its diameter.

Getting the job done can save your hydraulic system

By starting with knowing what cavitation is, its causes, and distinctive ways to identify it, end users can avoid taking the path that could lead to a compromised hydraulic system.

Another way to avoid systemic and hydraulic pump damage due to cavitation is to maintain preventative practices and measures.

 

In the end, it is always best to avoid a cavity by knowing the symptoms and doing the work to diagnose, correct and prevent a cavity.

Source Url:https://rexrothdistributor.in/avoiding-devastating-cavitation-damage/

 

Comments

Popular posts from this blog

The Effects of Summer Heat on a Hydraulic Fluid

As the summer heat rises in large facilities, businesses using fluid power systems must take steps to ensure their fluid power equipment is equipped to handle the high temperatures.   While cold weather is responsible for some liquid power system failures, hot weather has its own drawbacks.   By understanding how heat affects your fluid power system and preparing your fluid power systems for the summer season, you reduce risks to your hydraulic equipment that can lead to costly downtime and increased maintenance demands. In this article, you will find preparation information and tips to help you understand and mitigate the effects of heat on Rexroth valve hydraulic fluid . It is important to understand viscosity. Be sure to read and understand the viscosity chart for your oil to understand how oil viscosity changes at different operating temperatures.   The viscosity of petroleum-based hydraulic oil decreases with increasing temperature. This reduces its a...

3 Directional Control Valve Problems & Fixes

  Malfunctioning Direct Control Valves (DCVs) can cause problems in your customer's hydraulic system. You can quickly fix some DCV problems when the hydraulics are online. This article provides information on 3 DCV-related issues that the end user should be aware of. There are many ways DCVs can reduce system performance. The most common are sticky/non-slip, internal leaks, and external leaks. Problem #1: sticks/doesn't convert Most DCV valves use a sliding spool/bore design. When the valve is stuck, the spool cannot change its positions when the actuator is using normal force. Various factors can cause this sticking, including contamination, sediment, mechanical failure, or actuator failure. Let's take a look at these common causes. radioactive contamination When solid particulate contamination occurs between the orifice and the spool, the normal amount of force required to move the spool increases beyond the limits of the actuator. The spool gets stuck and will not move u...

Understanding variable displacement pumps

Almost all hydraulic applications use hydraulic pumps. The pump performs the task of converting mechanical energy into hydraulic energy. Take reservoir fluid and transfer it to other system components through pipes. From simple hand pumps to complex piston and gear pumps, you can find many classifications of hydraulic pump . A manual pump requires mechanical force to start the process, while complex pumps use electric motors to actuate hydraulic pumps. Forestry equipment, mining machinery, excavators, dump trucks, cranes, fireworks, loaders, etc. They use hydraulic pump applications. Positive displacement and non-positive displacement are the two main classifications of hydraulic pumps. Non-positive hydraulic pumps produce a continuous flow and a positive displacement pump produces a constant flow approximate to a constant speed regardless of pressure changes. Here, we will discuss a specific positive displacement pump called variable displacement pump. A variable displacement pump...